OPERATOR ERRORS
G031/G032 7-2 SM
Paper Misfeed
Message:
Remove Misfeed Front Cover & Tray
Remove Misfeed Open Front Cover
Definition:
There is a misfeed in the printer.
Reset Method:
Remove the misfed paper.
Toner Cartridge Installation Error
Message:
Replace Toner Cartridge
Definition:
The toner cartridge is not installated correctly or toner has almost run out.
Reset Method:
Set the toner cartridge correctly.
If the image density gets too light, replace the toner cartridge.
NOTE:
This machine only has a toner near-end sensor. There is no toner end
sensor.
Fusing Unit Installation Error
Message:
Replacing Fusing Unit
Definition:
The fusing unit is not installed correctly.
Reset Method:
Set the fusing unit correctly.
Maintenance Kit Replacing Time
Message:
Replace Maintenance Kit
Definition:
It is time to replace the parts in the maintenance kit.
Reset Method:
G031: Replace the maintenance kit.
G032: Replace the maintenance kit, then do the User Tools – Maintenance –
PM Clear procedure.