DIAGNOSTIC ERROR CODES
G031/G032 7-12 SM
Device. Code Description Possible Cause
0601
Addition error during floating point
operations with low accuracy mode
0602
Subtraction error during floating point
operations with low accuracy mode
0603
Division error during floating point
operations with low accuracy mode
0604
Multiplication error during floating point
operations with low accuracy mode
0605
Addition error during floating point
operations with high accuracy mode
0606
Subtraction error during floating point
operations with high accuracy mode
0607
Division error during floating point
operations with high accuracy mode
VR4300 FPU
0608
Multiplication error during floating point
operations with high accuracy mode
Printer Control Board
defective
Device. Code Description Possible Cause
0701 ASIC interrupt request error
0702 VR4300 interrupt request error
0703 Interrupt check error
0704 Interrupt mask error
ASIC Timer
0705 Timer frequency error
Printer Control Board
defective
Device. Code Description Possible Cause
0802 NVRAM verification check errorNVRAM
0804 Write error
Printer Control Board
defective
Device. Code Description Possible Cause
0901 Timeout error
0902
Interrupt request error of the ASIC when
the STROBE signal goes low
0903
Interrupt request error of the VR4300 when
the STROBE signal goes low
0904
Interrupt start error of the VR4300 when
the STROBE signal goes low
0905
Interrupt masking error when the STROBE
signal goes low
0906
Interrupt request error of the ASIC when
the STROBE signal goes high
0907
Interrupt request error of the VR4300 when
the STROBE signal goes high
0908
Interrupt start error of the VR4300 when
the STROBE signal goes high
0909
Interrupt masking error when the STROBE
signal goes high
ASIC P1284
090A
Interrupt request error of the ASIC when
the INIT signal goes low
Printer Control Board
defective