SIGNAL TABLE
SM 2-45 G031/G032
Detailed
Descriptions
CN Signal I/O Description
CN6-3 /FSET1 I Fusing unit 100V/200V selection
CN6-4 /FSET2 I Fusing unit 100V/200V selection
CN6-5 +5V
CN6-6 FTEMP I Fusing unit temperature detection (analog)
CN6-7 GND
CN6-8 /EXIT I Fusing exit sensor
CN6-9 +5V
P3 P4
CN7-1 +24V I
CN7-2 GND
CN7-3 XSMSTA O Polygon motor on signal
CN7-4 /SMLOK I Polygon motor lock signal
CN7-5 SMCK O Polygon motor clock signal
CN7-6 CHLDP O LD power signal (L: 600, H: 1200)
CN7-7 +5VS
CN7-8 APCSH O LD drive signal
CN7-9 GND
CN7-10 /VD O LD on signal
CN7-11 GND
CN7-12 /LD EN O LD drive enable signal
CN7-13 /DETP I Main scan synchronization signal
CN7-14 +5V
CN7-15 GND
CN8-1 +24V
CN8-2 GND
CN8-3 GND
CN8-4 +5V
CN8-5 SNDCK O 2nd PFU motor lock
CN8-6 XSNDFD O 2nd PFU motor on
CN8-7 XSNDCL O 2nd PFU paper end clutch on
CN8-8 SPSEN I 2nd PFU paper feed sensor
CN8-9 EPEND I 2nd PFU paper end detection
CN8-10 /OTSET I 2nd PFU paper detection
CN9-1 CHG2 O 2nd/3rd PFU sensor select
CN9-2 OPS0 I PFU paper size sensor signal
CN9-3 OPS1 I PFU paper size sensor signal
CN9-4 OPS2 I PFU paper size sensor signal
CN9-5 TRDCK O 3rd PFU paper feed motor lock
CN9-6 /TRDFD O 3rd PFU motor on
CN9-7 /TRDCL O 3rd PFU paper feed clutch on
CN9-8 TPSEN I 3rd PFU paper feed sensor
/FCSET I No cassette signal for 1st tray (G032)
CN9-9 OPNE0 I PFU paper near end condition
CN9-10 OPNE1 I PFU paper near end condition
CN9-11 OPS0 I PFU paper size detection
CN9-12 OPS1 I PFU paper size detection
CN9-13 OPS2 I PFU paper size detection
CN9-14 OPEND I PFU paper end detection
CN9-15 XOTSET I PFU paper detection