DIAGNOSTIC ERROR CODES
SM 7-15 G031/G032
Trouble-
shooting
Device. Code Description Possible Cause
1010 Formatting error
1011 Version error
Optional DIMM
1012
NVRAM version error
•
Optional DIMM
defective
•
Printer Control Board
defective
Device. Code Description Possible Cause
1102 SIMM size error: Unsupported SIMM size
1103 8MB SIMM check error
1104 16MB SIMM check error
Optional SIMM
1105 32MB SIMM check error
•
Optional SIMM
defective
•
Printer Control Board
defective
Device. Code Description Possible Cause
1201
The CPU did not receive the device ready
signal after the specified time.
1202
Interrupt request error of the ASIC in HDD
mode
1203
Interrupt request error of the VR4300 in
HDD mode
1204
Interrupt start error of the VR4300 in HDD
mode
1205 HDD interrupt masking error
1206 HDD register error
1207 HDD buffer RAM error
1208 HDD ECC error
1209 HDD ROM/RAM error
120A HDD diagnostic command error
120B HDD data transmission error
HDD
120C HDD read verification error
•
Optional HDD
defective
•
Printer Control Board
defective
Device. Code Description Possible Cause
1301 Initialization error
1302 Command timeout error
1303
Command reception interrupt request error
of the ASIC in NIB mode
1304
Command reception interrupt request error
of the VR4300 in NIB mode
1305
Command reception interrupt start error in
NIB mode
1306
Command reception interrupt masking
error in NIB mode
1307 NIB command error
NIB
1308 NIB buffer full error
•
Optional NIB
defective
•
Printer Control Board
defective